Skip to content

StageCommandGroup

Bases: CommandGroupBase

This command group contains functions for working with motorized stages. You are not meant to instantiate this class directly. Access it via the chuck or scope attribute of the SentioProber or via the SentioProber.probe class.

Example:

from sentio_prober_control.Sentio.ProberSentio import SentioProber

prober = SentioProber.create_prober("tcpip", "127.0.0.1:35555")
prober.scope.move_xy(XyReference.Current, 1000, 2000)

stage: Stage property

The stage this command group is for.

get_home(chuck_site=ChuckSite.Wafer)

Retrieves index coordinates of the home die.

Returns:

Type Description
Tuple[float, float, ChuckSite]

Row and column index of the home die.

get_site(site_idx)

Get information for a probe site.

Returns:

Name Type Description
id str

The site identifier.

x float

The x position in micrometer.

y float

The y position in micrometer.

ref XyReference

The position reference for the returned values.

enabled bool

True if the site is enabled, False otherwise.

get_site_num()

Returns the number of stage specific site position.

Returns:

Name Type Description
site_num int

An integer number of sites for the stage.

get_uvw(axis)

Get the position of a UVW axis of a SiPH positioner.

Wraps the remote command probe:{top|bottom}:{position}:get_uvw. Only available for probes with UVW axes.

Parameters:

Name Type Description Default
axis UvwAxis

The UVW axis to query.

required

Returns:

Type Description
float

The position of the axis in degree.

get_xy(ref_xy)

Returns the stage position for a given reference.

Parameters:

Name Type Description Default
ref_xy XyReference

The position reference for the submitted values.

required

Returns:

Name Type Description
x float

The x position in micrometer.

y float

The y position in micrometer.

ref XyReference

The position reference for the returned values.

get_z(ref_z)

Returns stage z-position.

Parameters:

Name Type Description Default
ref_z ZReference

The position reference for the submitted values.

required

Returns:

Name Type Description
z float

The x position in micrometer.

ref XyReference

The position reference for the returned values.

has_xy()

Returns true if stage has an xy drive.

Returns:

Name Type Description
has_xy_drive bool

True is the stage has a motorized xy drive.

has_z()

Returns true if stage has an z drive.

Returns:

Name Type Description
has_z_drive bool

True is the stage has a motorized z drive.

lift(lift)

Move stage to lift position.

Parameters:

Name Type Description Default
lift bool

If true, stage will move to lift position. If false, stage will move to separation position.

required

Returns:

Type Description
None

None

move_uvw(axis, value)

Move a UVW axis of a SiPH positioner to a position.

Wraps the remote command probe:{top|bottom}:{position}:move_uvw. Only available for probes with UVW axes.

Parameters:

Name Type Description Default
axis UvwAxis

The UVW axis to move.

required
value float

The target position of the axis in degree.

required

Returns:

Type Description
float

The position of the axis after the move in degree.

move_xy(ref, x, y)

Move stage to a given position.

Parameters:

Name Type Description Default
ref XyReference

The position reference for the submitted values.

required
x float

The x position in micrometer.

required
y float

The y position in micrometer.

required

Returns:

Name Type Description
xpos float

The x-position

ypos float

The y-position

ref XyReference

The position reference for the returned values.

move_z(ref, z)

Move stage to a given z position.

Parameters:

Name Type Description Default
ref ZReference

The position reference for the submitted values.

required
z float

The z position in micrometer.

required

Returns:

Name Type Description
zpos float

The z-position

ref ZReference

The position reference for the returned values.

set_home(x=None, y=None, site=None)

Set the stage home position.

Parameters:

Name Type Description Default
x float | None

The x position in micrometer.

None
y float | None

The y position in micrometer.

None
site ChuckSite | None

The chuck site to set the home position for.

None

Returns:

Name Type Description
x float

The x position in micrometer.

y float

The y position in micrometer.

site ChuckSite

The chuck site the home position was set for.

step_site(site)

Step to a specific site.

Parameters:

Name Type Description Default
site_idx str | int

The index or identifier of the site to step to.

required

Returns:

Name Type Description
id str

The site identifier.

x float

The x position in micrometer.

y float

The y position in micrometer.

step_site_first()

Step to the first site.

Returns:

Name Type Description
id str

The site identifier.

x float

The x position in micrometer.

y float

The y position in micrometer.

step_site_next()

Step to the first site.

Returns:

Name Type Description
id str

The site identifier.

x float

The x position in micrometer.

y float

The y position in micrometer.

handler: python options: members: StageCommandGroup